Consumer units and distribution boards
Each board is scanned with the covers off, with the building running as normal.
We use a thermal imaging camera to show hot spots in consumer units, distribution boards and connections. The survey runs while the building is in use, so in most cases nothing needs switching off.
Check us before you book
£395 minimum, plus VAT. Written report with photos.
Loose terminals, overloaded circuits and failing breakers can run hot before they trip or fail. A thermal camera shows that heat while the board is working.
Each board is scanned with the covers off, with the building running as normal.
We look at terminals, busbars, breakers and cable ends for heat that should not be there.
The power normally stays on, so shops, offices and factories can keep trading while we survey. If a board cannot be opened safely while live, we tell you before the visit.
A thermal photo and a normal photo of each board, the temperature of any hot spot, what it means and what we recommend.
| Service | Guide price |
|---|---|
| On its own | £35 per board£395 minimum, plus VAT |
| Added to a commercial EICR or fixed wire test | From £99 plus VATDone in the same visit |
Not sure how many boards you have? Tell us the building and we will estimate before you commit.
A thermal survey finds heat while the system is live. The result is a survey report. It is not an EICR certificate. For the wiring tests, see commercial EICR and fixed wire testing.
Some insurers ask for a thermal survey of the electrical panels, in some cases every year. Check your policy or ask your broker what yours needs. If they want the survey done by a certified thermographer, tell us before you book.
Heat only shows when current flows. We survey while the building is running as normal, and we say in the report if a board was lightly loaded.
Add it to a commercial EICR or fixed wire test, or book it on its own. See also electrical and fire safety compliance in Sheffield.
On its own it is £35 per board, £395 minimum, plus VAT. Added to a commercial EICR or fixed wire test it is from £99 plus VAT. Call 07305 434759 for a quote by the number of boards.
Usually not. The survey runs with the system on and under normal load. Boards need to be reachable and we open the covers. If a board cannot be opened safely while it is live, we tell you before the visit.
A short report with a thermal photo and a normal photo of each board, the temperature of any hot spot, what it means and what we recommend. We can often fix small faults while we are there, or we quote for them after the survey.
No. An EICR tests the fixed wiring and gives a certificate. A thermal survey looks for heat in the boards and connections and gives a report.
Some insurers ask for a thermal survey of electrical panels. Ask your insurer or broker what your policy requires, and tell us before you book if they want a certified thermographer.
Offices, shops, schools, factories and blocks of flats, plus landlords and letting agents.